WhatsApp Chat with us
Welcome to our company
Change Language
SIEMENS Envitec Oxygen Sensor
SIEMENS Envitec Oxygen Sensor

SIEMENS Envitec Oxygen Sensor

MOQ : 1 Unit

SIEMENS Envitec Oxygen Sensor Specification

  • Cable Length
  • Custom, as per OEM requirement
  • Operating Temperature
  • 0C to 40C
  • Signal Type
  • Analog
  • Measurement Range
  • 0-100% O2
  • Mounting Type
  • Threaded/Capsule
  • Wireless
  • No
  • Features
  • Long Life, Stable Output, Maintenance Free
  • Sensitivity
  • High, suitable for low and high oxygen concentrations
  • Interface
  • Direct connection to medical device
  • IP Rating
  • IP22
  • Application
  • Respiratory and Medical Devices
  • Sensor Type
  • Galvanic Oxygen Sensor
  • Response Time
  • <15 sec (T90)
  • Power Consumption
  • Self-powered (no external supply required)
  • Product Type
  • SIEMENS Envitec Oxygen Sensor
  • Material
  • Plastic
  • Input
  • Ambient Oxygen
  • Output
  • Analog Voltage Signal
  • Function
  • Measures oxygen concentration in gases
  • Usage
  • Industrial
  • Accuracy
  • 1% of Full Scale
  • Resolution
  • 0.1% O2
  • Voltage
  • 220-440 Volt (v)
  • Weight
  • Approx. 45 grams
  • Compensation
  • Temperature compensated
  • Storage Temperature
  • -20C to +50C
  • Connector Type
  • 2-Pin/3-Pin (OEM specific)
  • Humidity Range
  • 0-99% RH (Non-condensing)
  • Replacement Interval
  • As indicated by calibration drift
  • Warm-up Time
  • None required
  • Lifespan
  • Approx. 1,000,000 Oxygen percent-hours
  • Operating Pressure
  • Atmospheric
 

SIEMENS Envitec Oxygen Sensor Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash Advance (CA)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 14 Days
  • Main Domestic Market
  • All India
 

About SIEMENS Envitec Oxygen Sensor

SIEMENS Envitec Oxygen Sensor is utilized to measure the oxygen concentration in a patient's blood. The sensor is designed to be used in conjunction with a patient monitoring system, such as a pulse oximeter or blood gas analyzer. SIEMENS Envitec Oxygen Sensor consists of a small sensor electrode that is placed on the patient's skin or in a blood vessel. Our offered oxygen sensor can provide real-time measurements of the patient's oxygen levels, allowing healthcare providers to quickly detect and respond to changes in the patient's condition. Moreover, this oxygen sensor is known for its accuracy and reliability, making it a valuable tool in critical care settings such as intensive care units, operating rooms, and emergency departments.



Highly Accurate Oxygen Sensing

Engineered for precision, the SIEMENS Envitec Oxygen Sensor delivers up to 1% full scale accuracy and 0.1% O2 resolution. Its galvanic sensor type ensures high sensitivity and fast response, making it suitable for spot-on measurements in both low and high oxygen concentration environments, especially within respiratory and medical devices.


Low Maintenance and Long Lifespan

Designed for continuous operation, this sensor requires no warm-up time and stays virtually maintenance free. It achieves a remarkable lifespan of approximately 1,000,000 oxygen percent-hours, with replacement intervals determined by calibration drift. Its stable output reduces downtime and maintenance interventions, providing peace of mind for users.


Flexible Installation Options

With both threaded and capsule mounting types and cable lengths tailored to your OEM specifications, installation is adaptable to various devices. The analog output and direct interface make integration into existing systems straightforward, while its IP22 rating ensures robustness against environmental factors in typical medical and industrial use.

FAQ's of SIEMENS Envitec Oxygen Sensor:


Q: How is the SIEMENS Envitec Oxygen Sensor typically installed?

A: The sensor can be installed using threaded or capsule mounting options, and it connects directly to compatible medical or industrial devices using a 2-pin or 3-pin configuration, with cable length customized according to OEM needs.

Q: What is the recommended process for replacing the sensor?

A: Replacement is advised when significant calibration drift is noticed, which can be identified during routine calibration checks. The sensor is maintenance free, and no special warm-up is required before or after replacement.

Q: Where can the SIEMENS Envitec Oxygen Sensor be used?

A: This sensor is ideal for use in respiratory and medical devices, as well as in various industrial applications requiring precise oxygen monitoring under atmospheric pressure and a wide humidity range (0-99% RH, non-condensing).

Q: What are the main benefits of using this oxygen sensor in medical applications?

A: The main advantages include high measurement accuracy, fast response time, long operational lifespan, stable analog output, and no need for external power supply, ensuring reliable monitoring for patient safety and process control.

Q: How does the sensor compensate for temperature variations during operation?

A: The SIEMENS Envitec Oxygen Sensor features built-in temperature compensation, which maintains stable and accurate readings even as ambient temperatures fluctuate between 0C and 40C.

Q: When should the sensor be replaced to ensure optimal performance?

A: Sensor replacement is recommended when calibration checks indicate significant drift or loss of accuracy, typically after extended use approaching its lifespan of 1,000,000 oxygen percent-hours.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top