In order to maintain accurate and effective airflow control in ventilators and respiratory devices, ventilator flow sensors are essential parts of contemporary medical equipment. These sensors are crucial in critical care settings, ERs, and during operations because they monitor and regulate the flow of oxygen and other gases into a patient's airway. Ventilator Flow Sensors give healthcare workers the ability to precisely measure the volume and speed of air given to the patient, allowing them to customize ventilation settings to meet each patient's unique demands, maximizing respiratory support and improving patient comfort.

Biometric Anesthesia Flow Sensor

MOQ : 1 Unit

  • Accuracy
  • 1.5% F.S.
  • Application
  • Hospital, Medical, Clinical Use
  • Cable Length
  • 2 meters
  • Features
  • Highly accurate, Fast response, Medical grade, Easy installation
  • Function
  • Measures and monitors anesthesia gas flow rates
  • IP Rating
  • IP42
  • Input
  • Gas Flow
  • Interface
  • RS232/Analog
  • Material
  • Plastic
  • Measurement Range
  • 0-20 L/min
  • Mounting Type
  • Inline
  • Operating Temperature
  • 0C to 50C
  • Output
  • Analog/RS232 Digital
  • Power Consumption
  • <1W
  • Product Type
  • Biometric Anesthesia Flow Sensor
  • Resolution
  • 0.01 L/min
  • Response Time
  • 80 ms
  • Sensitivity
  • 0.005 L/min
  • Sensor Type
  • Biometric Flow Sensor
  • Signal Type
  • Other, Linear Output
  • Usage
  • Industrial
  • Voltage
  • 220-440 Volt (v)
  • Warranty
  • 1 Year
  • Weight
  • Approx. 120g
  • Wireless
  • No

Drager Ventilator Flow Sensor

MOQ : 1 Unit

  • Accuracy
  • 4% of reading or 0.02 L/min
  • Application
  • ICU, NICU, mechanical ventilation monitoring
  • Cable Length
  • Not applicable (direct plug-in)
  • Features
  • Disposable, lightweight, high precision, compatible with multiple Drager ventilator models
  • Function
  • Measures inspiratory and expiratory gas flow
  • IP Rating
  • IP22
  • Input
  • Gas flow from ventilator circuit
  • Interface
  • Proprietary Drager connector
  • Material
  • Glass
  • Measurement Range
  • 0 to 180 L/min
  • Mounting Type
  • In-line, clip-on with connector
  • Operating Temperature
  • -10C to +50C
  • Output
  • Analog / Digital signal to ventilator
  • Power Consumption
  • < 1 Watt
  • Product Type
  • Drager Ventilator Flow Sensor
  • Resolution
  • 0.01 L/min
  • Response Time
  • < 10 ms
  • Sensitivity
  • 0.02 L/min
  • Sensor Type
  • Hot-wire anemometer
  • Signal Type
  • Other, Flow-dependent voltage
  • Usage
  • Industrial
  • Voltage
  • 220-440 Volt (v)
  • Warranty
  • 1 Year
  • Weight
  • Approx. 15 g
  • Wireless
  • No