Product Details:

  • Power Consumption < 1 Watt
  • Response Time < 10 ms
  • Cable Length Not applicable (direct plug-in)
  • Sensitivity 0.02 L/min
  • Wireless No
  • Signal Type Flow-dependent voltage
  • IP Rating IP22
  • Click to View more
X

Drager Ventilator Flow Sensor Price And Quantity

  • 1 Unit
  • Individually packed in sterile pouch
  • Bidirectional
  • Transparent/Translucent
  • < 0.5 cm H2O at 60 L/min
  • Yes
  • Specific to Drager ventilators
  • 0-100% RH non-condensing
  • Meets ISO 80601-2-12 for ventilator components
  • Factory calibrated, maintenance-free
  • Single-use, non-sterilizable
  • Tested per ISO 10993
  • -20C to +60C

Drager Ventilator Flow Sensor Product Specifications

  • Proprietary Drager connector
  • Approx. 15 g
  • -10C to +50C
  • Industrial
  • 4% of reading or 0.02 L/min
  • ICU, NICU, mechanical ventilation monitoring
  • Measures inspiratory and expiratory gas flow
  • Disposable, lightweight, high precision, compatible with multiple Drager ventilator models
  • 0.01 L/min
  • Hot-wire anemometer
  • 0 to 180 L/min
  • In-line, clip-on with connector
  • IP22
  • Flow-dependent voltage
  • Not applicable (direct plug-in)
  • 0.02 L/min
  • No
  • 1 Year
  • Drager Ventilator Flow Sensor
  • 220-440 Volt (v)
  • < 10 ms
  • Glass
  • Analog / Digital signal to ventilator
  • < 1 Watt
  • Gas flow from ventilator circuit
  • Individually packed in sterile pouch
  • Bidirectional
  • Transparent/Translucent
  • < 0.5 cm H2O at 60 L/min
  • Yes
  • Specific to Drager ventilators
  • 0-100% RH non-condensing
  • Meets ISO 80601-2-12 for ventilator components
  • Factory calibrated, maintenance-free
  • Single-use, non-sterilizable
  • Tested per ISO 10993
  • -20C to +60C

Drager Ventilator Flow Sensor Trade Information

  • Cash Advance (CA)
  • 10 Unit Per Month
  • 7-10 Days
  • All India

Product Description

Drager Ventilator Flow Sensor is utilized in mechanical ventilation to measure the flow of gases through the breathing circuit. It is a small, lightweight component that is integrated into the ventilator system. Drager Ventilator Flow Sensor is made of lightweight materials to minimize its impact on the patient's breathing and is designed to be easy to clean and maintain. Our offered flow sensor is basically an important component of mechanical ventilation, as it helps to ensure that the patient is receiving the correct amount of gas at the right pressure and volume.



Ensuring Patient Safety with Single-Use, Sterile Sensors

This flow sensor is individually packed in a sterile pouch, eliminating the risks of cross-contamination between patients. Its single-use design aligns with modern infection control practices and is especially suitable for sensitive hospital environments. Being non-sterilizable and maintenance-free, it simplifies staff workflow while assuring consistent performance in every application.


Uncompromised Accuracy and Fast Response

Engineered with a hot-wire anemometer sensor and factory calibrated for accuracy, this device measures gas flows with high precision (resolution: 0.01 L/min; accuracy: 4% of reading or 0.02 L/min). With a response time of less than 10 ms, it captures rapid flow changes, ensuring optimal ventilator monitoring for both adult and neonatal patients.


Compatibility and Compliance for Medical Reliability

The sensor interfaces seamlessly with multiple Drager ventilators using a proprietary connector. It meets stringent ISO 80601-2-12 and ISO 10993 standards for safety and biocompatibility, making it a trusted component in critical care settings. Its low resistance and reliable output contribute to improved ventilator performance and patient outcomes.

FAQ's of Drager Ventilator Flow Sensor:


Q: How is the Drager Ventilator Flow Sensor sterilized and packaged?

A: The sensor is packaged individually in a sterile pouch at the factory and is intended for single use only. It is not designed to be sterilized by the user or reused, eliminating the possibility of cross-contamination.

Q: What are the main benefits of using this flow sensor in ICU or NICU settings?

A: Benefits include maintenance-free operation, reliable factory calibration, high accuracy and fast response time, single-use sterility for infection control, and compatibility with several Drager ventilator models, ensuring enhanced patient safety and precise respiratory monitoring.

Q: When should the Drager Ventilator Flow Sensor be replaced?

A: The sensor should be replaced after each patient use or as directed by hospital infection control protocols. Since it is designed for single-patient use and cannot be sterilized, proper disposal after use is critical.

Q: Where is this sensor installed in the ventilator system?

A: The sensor mounts in-line, directly clipping onto the ventilator circuit using its proprietary Drager connector. It requires no additional cables or adaptations, ensuring a secure and effective installation.

Q: What is the process for connecting the flow sensor to a Drager ventilator?

A: Simply unseal the sterile package and attach the flow sensor to the appropriate port on your Drager ventilator using the proprietary connector. No calibration or specialized setup is necessary due to its factory calibration.

Q: How does the flow sensor provide accurate measurements during ventilation?

A: The sensor utilizes a hot-wire anemometer to deliver precise, real-time measurements of both inspiratory and expiratory gas flow, supporting accurate ventilator settings and patient monitoring.

Q: What ensures the safety and regulatory compliance of this sensor for hospital use?

A: The sensor is tested for biocompatibility under ISO 10993 standards, complies with ISO 80601-2-12 for ventilator components, and is latex-free, ensuring suitability and safety for both adult and neonatal patients.